SU-8 masters for anisotropic-colloid microfluidics

Application Library / Microfluidics Thesis SU-8 masters for anisotropic-colloid microfluidics SU-8 masters on three-inch silicon wafers were prepared for two- and three-dimensional microfluidic focusing of anisotropic colloids. How Cee® equipment is used SU-8 masters on three-inch silicon wafers were prepared for two- and three-dimensional microfluidic focusing of anisotropic colloids. Equipment reported Cee 200X spin coater […]

Wafer-track edge-bead removal for microinductors

Application Library / Edge Bead Removal (EBR) Thesis Wafer-track edge-bead removal for microinductors A Brewer Cee track removed resist from wafer perimeters with PGMEA during lithography for electrodeposited structures and released microinductors. How Cee® equipment is used A Brewer Cee track removed resist from wafer perimeters with PGMEA during lithography for electrodeposited structures and released […]

Microchannel masters for biochemical electrophoresis

Application Library / Bio Thesis Microchannel masters for biochemical electrophoresis SU-8 was dynamically dispensed and spin-coated onto four-inch silicon wafers to form PDMS microchannel masters for biochemical electrophoresis. How Cee® equipment is used SU-8 was dynamically dispensed and spin-coated onto four-inch silicon wafers to form PDMS microchannel masters for biochemical electrophoresis. Equipment reported Cee 200CB […]

SU-8 masters for electrokinetic cell-culture chips

Application Library / Bio Thesis SU-8 masters for electrokinetic cell-culture chips SU-8 master fabrication includes calibration of static and dynamic dispensing for electrokinetically pumped cell-culture microfluidic chips. How Cee® equipment is used SU-8 master fabrication includes calibration of static and dynamic dispensing for electrokinetically pumped cell-culture microfluidic chips. Equipment reported Cee 200CB spin coater Source […]

Comparison of separation modes for microchip electrophoresis of proteins

Application Library / Microfluidics Paper / report Comparison of separation modes for microchip electrophoresis of proteins Fabricate SU-8 channel molds for comparing protein-separation modes in microchip electrophoresis. The methods distinguish the Brewer Science coater from the Thermo Scientific hotplate. How Cee® equipment is used Fabricate SU-8 channel molds for comparing protein-separation modes in microchip electrophoresis. […]

Automated single cell isolation from suspension with computer vision

Application Library / Bio Paper / report Automated single cell isolation from suspension with computer vision Make SU-8 replicas for PDMS microwell arrays used in computer-vision-guided single-cell isolation. The procedure specifies Cee 200CBX coating at 3,000 rpm. How Cee® equipment is used Make SU-8 replicas for PDMS microwell arrays used in computer-vision-guided single-cell isolation. The […]

Multifunctional Freestanding Microprobes for Potential Biological Applications

Application Library / Bio Paper / report Multifunctional Freestanding Microprobes for Potential Biological Applications Pattern SU-8 on stainless steel for freestanding biological microprobes. The fabrication procedure names the 200X and reports a 4,000 rpm, 60-second coating step. How Cee® equipment is used Pattern SU-8 on stainless steel for freestanding biological microprobes. The fabrication procedure names […]

Jeffamine derivatized TentaGel beads and poly(dimethylsiloxane) microbead cassettes for ultrahigh-throughput in situ releasable solution-phase cell-based screening of one-bead-one-compound combinatorial small molecule libraries

Application Library / Bio Paper / report Jeffamine derivatized TentaGel beads and poly(dimethylsiloxane) microbead cassettes for ultrahigh-throughput in situ releasable solution-phase cell-based screening of one-bead-one-compound combinatorial small molecule libraries Fabricate SU-8 molds for PDMS bead cassettes used in high-throughput screening of releasable combinatorial compound libraries. The procedure explicitly assigns spin and bake settings to the […]

A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection

Application Library / Microfluidics Paper / report A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection Coat SU-8 on silicon to fabricate channels for a chip-based electrophoresis system combining electrochemical detection with hydrodynamic injection. How Cee® equipment is used Coat SU-8 on silicon to fabricate channels for a chip-based electrophoresis system combining electrochemical detection […]

Single cell-resolution western blotting

Application Library / Bio SOP / protocol Single cell-resolution western blotting Prepare photoresist-coated glass masters for microwell gels used in single-cell western blotting. The protocol identifies the coater and provides the wafer-coating procedure. How Cee® equipment is used Prepare photoresist-coated glass masters for microwell gels used in single-cell western blotting. The protocol identifies the coater […]

SEMICON EUROPA · 10–13 NOVEMBER

Bring your process questions.

Meet Jacob, CEE’s Global Sales Director, in Munich with our partner SiSTEM Technology.

Stand C1353 · Messe München
Spin coating, bake and chill, temporary bonding and debonding.

Book a stand meeting →

Mention Jacob from CEE in SiSTEM’s booking form.