Continuous monitoring of adenosine and its metabolites using microdialysis coupled to microchip electrophoresis with amperometric detection
Application Library / Microfabrication Paper / report Continuous monitoring of adenosine and its metabolites using microdialysis coupled to microchip electrophoresis with amperometric detection The study reports SU-8 microchips for adenosine/metabolite monitoring. How Cee® equipment is used A Cee® 100 is used in SU-8 processing for microchip fabrication. The platform couples microdialysis to electrophoresis and amperometric […]
Conjugated polymer blends for faster organic mixed conductors
Application Library / Material Science Paper / report Conjugated polymer blends for faster organic mixed conductors The study reports conjugated-polymer film coating for organic mixed conductors. How Cee® equipment is used The supplementary methods identify a Brewer Science 200CBX for conjugated-polymer film application. The films are used to study transport in organic mixed conductors. Equipment […]
Self-assembled single-crystal silicon circuits on plastic
Application Library / Material Science Paper / report Self-assembled single-crystal silicon circuits on plastic The study reports SU-8 layers for self-assembled single-crystal silicon circuits on plastic. How Cee® equipment is used A Cee® 100 is used to apply SU-8 layers in the fabrication of single-crystal silicon circuits on plastic. The paper studies self-assembly of the […]
Impact of crowding on the diversity of expanding populations
Application Library / Bio Paper / report Impact of crowding on the diversity of expanding populations The study reports SU-8 master molds for studying crowding in expanding cell populations. How Cee® equipment is used The study identifies a Cee® 100 in SU-8 master-mold fabrication. The microfabricated environments are used to study how crowding affects expanding […]
Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway
Application Library / Microfabrication Paper / report Microchip electrophoresis with electrochemical detection for the determination of analytes in the dopamine metabolic pathway The study reports SU-8 microchip molds for dopamine-metabolite electrophoresis. How Cee® equipment is used A Cee® 100 applies SU-8 during microchip master fabrication. The resulting electrophoresis platform is used for electrochemical detection of […]
Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations
Application Library / Microfabrication Paper / report Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations The study reports SU-8 channel molds for reverse-polarity amperometric electrophoresis. How Cee® equipment is used The microchip fabrication method identifies a Cee® 100 for SU-8 processing. The dual-channel device […]
Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles
Application Library / Microfabrication Paper / report Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles The study reports LOR/S1813 lithography for individual battery-particle microelectrode arrays. How Cee® equipment is used The electrode-array fabrication method identifies an Apogee® spinner for LOR and S1813 resist processing. The arrays enable electrochemical cycling of individual battery particles. Equipment […]
Ultralow-ri materials, low-k dielectric materials, composites, and methods
Application Library / Material Science Patent Ultralow-ri materials, low-k dielectric materials, composites, and methods The patent reports low-index dielectric film coating on reclaimed silicon wafers. How Cee® equipment is used The patent examples identify an Apogee® spin coater for applying low-refractive-index dielectric materials to reclaimed silicon wafers. This entry describes experimental film preparation reported in […]
Minimal invasive electrocorticographic brain-computer interface
Application Library / Lithography Patent Minimal invasive electrocorticographic brain-computer interface The patent reports photoresist prebaking for minimally invasive electrocorticographic interfaces. How Cee® equipment is used The patent's fabrication description identifies an Apogee® bake plate for photoresist prebaking. The application is an electrocorticographic brain-computer interface; an exact bake-plate size is not inferred. Equipment reported Apogee bake […]
Performance and scaling effects in a multilayer microfluidic extracorporeal lung oxygenation device
Application Library / Microfabrication Paper / report Performance and scaling effects in a multilayer microfluidic extracorporeal lung oxygenation device The study reports PDMS gas-transfer membrane coating for a multilayer artificial-lung device. How Cee® equipment is used A Cee® 100 is used to form PDMS gas-transfer membranes. The membranes are incorporated into a multilayer microfluidic oxygenator […]